Timber Frame Specification
 

 

Whilst each project is different & requires an element of individuality when it comes to the schedule of materials supplied the list below sets a good standard of specification from which any fine tuning can be done. The left hand 2 columns list the area of structure & standard specification of an Oakworth Homes Kit. The right hand column lists any optional extra/specification upgrade that may be required. Our team will ensure you have the current information to allow you to fine tune your requirements on your next project.

 
 

Area of construction

Standard supply

Optional Specification Upgrade / Extras

Design & Engineering

Standard supply

Optional Specification Upgrade / Extras

Calculation

As project requirements in accordance with local building regulations

 

Drawings

Foundation plan, Panel drawings, Roof plan

 

Floors

Standard supply

Optional Specification Upgrade / Extras

First & intermediate floor joists

Engineered I joist

Pozi Joist

Floor bracing / nogging

Section as respective floor joists

Steel bracing as engineers detail

Flooring

22mm moisture resistant T & G chipboard

22mm moisture resistant T & G chipboard with peel clean covering taped and sealed at joints

Walls

Standard supply

Optional Specification Upgrade / Extras

External wall panels

38 x 140 C16 CLS framing at 600mm centres

 

 

140 x 220 timber lintels to openings

 

 

Single row of centre noggings

 

 

9mm O.S.B.3 sheathing to B.B.A. approval

 

 

breather membrane conforming to building regulation standards

Low 'e' breather membrane

 

Clearly marked wall tie fixing points

 

Internal wall panels

38 x 90 CLS framing at 600mm centres

 

 

90 x 220 timber lintels at openings

 

 

Single row of centre noggings

 

Partition wall panels to a joining apartments, staircase & lobby

38 x 90 CLS framing at 600mm centres with 9mm OSB3 sheathing

38 x 140 C16 CLS framing at 600mm centres

 

90 x 220 timber lintels at openings

 

 

Single row of centre noggings

 

Sole plates

38 x 140 Treated C16 & 38 x 90 Treated as required

 

Head binder

38 x 140 C16 38 x 90 as required

 

Fire stops

50 x 50 whitewood

 

Fire-sock

50mm  Isowool or similar

 

External protrusion framing

50 x 50 whitewood

 

Plumbing/Electrical support noggings

38 x 90 whitewood

 

Fixings for above

All supplied as needed

 

Damp Proof Course

Supplied to suit frame erection requirements

 

Packing (frame levelling)

Supplied as required up to 18mm

 

Roof Standard Supply Optional Specification Upgrade / Extras
Gable end wall panels 38 x 140 C16 to suit design at 600 centres  
  9mm O.S.B. sheathing to B.B.A. approval  
  breather membrane conforming to building regulation standards Low 'e' breather membrane
  Single row of centre nogging as detailed by engineer  
Spandrel panels 38 x 90 C16 to suit engineers design at 600 centres  
  Plaster board to spandrel panels  
Roof trusses at 600c/s To suit individual project design & specification  
Loose timber Supplied loose to suit engineered design  
Structural fixings Gal  

 

     